External wall insulation · Greater London
External wall insulation in Ilford
External wall insulation in Ilford: free survey, written specification and a fixed price, with the details that keep walls dry planned from the start. Whole-house jobs and single elevations are both quoted in Ilford; a cold gable or rear wall can be done on its own where it suits.
- Free survey in IG1 and nearby
- Guide price from £105 per m² + scaffold, 0% VAT
- Fixed written price before work starts
Free survey in Ilford
Postcode, service and a phone number is all we need.
Part of every quote
- Work happens outside, so you can live at home throughout
- Cills, pipes, vents, meter boxes and the roofline detailed as part of the job
- Typically takes a 225mm solid brick wall from around 2.1 W/m²K to about 0.30 W/m²K with 90–110mm of board
- Installing wall insulation in homes is currently zero-rated for VAT until 31 March 2027

Homes and walls in Ilford
Surveys in Ilford also cover the surrounding IG1 district and towns such as Barking and Becontree. London's housing includes a large stock of Victorian and Edwardian solid-wall terraces, inter-war semis and post-war blocks, and conservation areas cover many streets — so planning is often the first question for external work.
Much of Greater London sits in the lower wind-driven rain exposure bands, which keeps the choice of finishes wide — though hilltop, coastal and exposed gable walls can still need a tougher specification, so we check the actual site.
For homes in Ilford, the survey starts with the wall itself: solid brick, stone or concrete, and whether any old render is sound enough to insulate over.
- Postcode district
- IG1
- County or area
- Greater London
- Nation
- England
- Nearby
- Barking, Becontree, Leytonstone, Stratford
Approvals in England
Planning in Ilford follows England's national rules: similar-looking finishes on houses are usually permitted, while flats, commercial premises, conservation areas and streets under an Article 4 direction need an application.
If the work covers more than half of a wall, or a quarter of the building's whole envelope, it counts as renovating a thermal element, with a target of about 0.30 W/m²K where feasible.
Which homes is EWI suited to?
EWI is mainly used on solid-walled houses (most homes built before about 1920), on post-war concrete and steel-framed houses, on homes where cavity fill isn't possible, and on bungalows and park homes. It also suits flats and blocks where the whole building is treated at once.
It is less straightforward where the walls face a pavement with no room to project, on listed buildings, or where planning rules want the existing brick or stone left visible. A survey picks these up before you commit.
External wall insulation prices in Ilford
| Item | Guide price | Notes |
|---|---|---|
| EPS system with silicone render | £105–£145 per m²0% VAT | Most common choice for houses |
| Mineral wool system | £125–£170 per m²0% VAT | Non-combustible, vapour-open |
| Brick-slip finish over insulation | £185–£260 per m²0% VAT | Where a brick look is wanted |
| Three-bed semi, EPS + silicone (incl. scaffold) | £10,200–£17,7000% VAT | 80–100 m² of wall; depends on detailing and access |
Confirmed by a fixed written quote after survey. 0% VAT: installing insulation in a home is zero-rated until 31 March 2027, so these figures are the total; 5% applies from 1 April 2027.
From enquiry to finished wall
Tell us about the property
Use the quote tool or form, or call. Photos help.
Free survey
We measure, check the walls and confirm approvals.
Fixed written quote
System, details, access, exclusions and VAT in writing.
Installation
Scheduled for suitable weather, with a clear programme.
External wall insulation in Ilford: questions
Does external wall insulation cause damp?
Not when it is specified and detailed properly. Problems usually come from poor detailing: no starter track above the damp-proof course, gaps at cills and penetrations, or a vapour-closed system on a wall that needs to breathe. The survey checks moisture, ground levels and the wall type before a system is chosen.
Does EWI need Building Regulations approval?
In England and Wales, usually. Insulating more than half of a wall's area, or more than a quarter of the building's whole external envelope, counts as renovating a thermal element, so building control needs to be involved and the wall should reach about 0.30 W/m²K where that's practical. Scotland and Northern Ireland have their own building standards processes.
How long does external wall insulation last?
A well-installed render system is commonly expected to last 25–30 years or more, with occasional cleaning and inspection of sealants. The system manufacturer's documentation states the expected service life for the specific build-up.
Do you cover Ilford?
Yes — we survey and quote external wall insulation in Ilford (IG1) and nearby Barking, Becontree and Leytonstone, with a fixed written price before any work starts.