Free survey · Fixed written price · UK-wideCall free 0800 088 6248

External wall insulation · Greater Glasgow

External wall insulation in Bearsden

We quote external wall insulation for homes in Bearsden (G61) and nearby Clydebank and Renfrew, with guide prices online and a free survey to fix the price. For homes in Bearsden, the survey starts with the wall itself: solid brick, stone or concrete, and whether any old render is sound enough to insulate over.

  • Free survey in G61 and nearby
  • Guide price from £105 per m² + scaffold, 0% VAT
  • Fixed written price before work starts

Free survey in Bearsden

Postcode, service and a phone number is all we need.

Enter a valid UK postcode.

Choose a service.

Enter your name.

Enter a phone number we can call.

Check the email address.

We use your details only to respond to this enquiry. See our privacy notice.

Part of every quote

  • Covers tired brick, pebble dash or failing render with a new finish
  • Installing wall insulation in homes is currently zero-rated for VAT until 31 March 2027
  • Boards chosen for the wall: EPS, mineral wool, wood fibre or phenolic
  • Typically takes a 225mm solid brick wall from around 2.1 W/m²K to about 0.30 W/m²K with 90–110mm of board
Side gable of a semi-detached house part-way through external wall insulation, with mineral wool slabs, mesh base coat and finished white render

Local considerations in Bearsden

We also cover Clydebank and Renfrew, close to Bearsden. Bearsden is about 5 miles from Glasgow. West Central Scotland has sandstone tenements, interwar and post-war council housing including no-fines and other system-built types, and many harled (roughcast) houses.

Parts of Greater Glasgow fall in the higher wind-driven rain exposure bands, especially coastal and upland sites, so render specification, movement joints and detailing at cills, verges and the base of the wall matter more than usual.

We plan EWI in Bearsden around the details that cause trouble later — cills, eaves, downpipes and the base of the wall above the damp-proof course.

Postcode district
G61
County or area
Greater Glasgow
Nation
Scotland
Nearby
Clydebank, Renfrew, Bishopbriggs, Glasgow

Scotland: planning and regulations

For Bearsden properties, flats and tenements need planning permission for external insulation, and a noticeable change of finish on a house often does too under Scottish rules.

Over-cladding work in Scotland often needs a building warrant from the council's building standards service, with Section 6 of the Technical Handbooks setting insulation benchmarks.

How does external wall insulation work?

Heat moves out through a wall faster when the wall is solid or poorly insulated. EWI wraps the outside face in a continuous layer of insulation, so the masonry stays on the warm side and the cold bridges at floor and party-wall junctions are reduced. The boards are bonded with adhesive and, on most walls, mechanically fixed. A base coat with an embedded glass-fibre mesh goes over the top, then a primer and the decorative finish.

Because the wall itself sits inside the insulation, it stays warmer and drier, and the rooms keep their full size. That is the main difference from internal insulation.

External wall insulation prices in Bearsden

External wall insulation guide prices
ItemGuide priceNotes
EPS system with silicone render£105–£145 per m²0% VATMost common choice for houses
Mineral wool system£125–£170 per m²0% VATNon-combustible, vapour-open
Brick-slip finish over insulation£185–£260 per m²0% VATWhere a brick look is wanted
Three-bed semi, EPS + silicone (incl. scaffold)£10,200–£17,7000% VAT80–100 m² of wall; depends on detailing and access

Confirmed by a fixed written quote after survey. 0% VAT: installing insulation in a home is zero-rated until 31 March 2027, so these figures are the total; 5% applies from 1 April 2027.

What happens next

  1. Tell us about the property

    Use the quote tool or form, or call. Photos help.

  2. Free survey

    We measure, check the walls and confirm approvals.

  3. Fixed written quote

    System, details, access, exclusions and VAT in writing.

  4. Installation

    Scheduled for suitable weather, with a clear programme.

External wall insulation in Bearsden: questions

How much does external wall insulation cost?

Our guide price for EWI is £105–£170 per m² of wall depending on the system, plus scaffolding. A typical three-bed semi with EPS and silicone render comes to roughly £10,200–£17,700 for the whole house, including scaffold. Installing insulation in a home is zero-rated for VAT until 31 March 2027, so that's the total. You get a fixed written price after a free survey.

How long does external wall insulation last?

A well-installed render system is commonly expected to last 25–30 years or more, with occasional cleaning and inspection of sealants. The system manufacturer's documentation states the expected service life for the specific build-up.

Does external wall insulation cause damp?

Not when it is specified and detailed properly. Problems usually come from poor detailing: no starter track above the damp-proof course, gaps at cills and penetrations, or a vapour-closed system on a wall that needs to breathe. The survey checks moisture, ground levels and the wall type before a system is chosen.

Do you cover Bearsden?

Yes — we survey and quote external wall insulation in Bearsden (G61) and nearby Clydebank, Renfrew and Bishopbriggs, with a fixed written price before any work starts.

External wall insulation in Bearsden

Send your postcode and we'll arrange a survey in Bearsden.

Call freeGet a quote